Impacts of Pollution: Leaking Septic Tanks on Groundwater Quality in Owerri Southeastern, Nigeria

Nwugha, V. N. and Okeke, P. I. and Emeronye, U. R. (2021) Impacts of Pollution: Leaking Septic Tanks on Groundwater Quality in Owerri Southeastern, Nigeria. In: Current Approaches in Science and Technology Research Vol. 5. B P International, pp. 103-111. ISBN 978-93-91215-53-8

Full text not available from this repository.

Abstract

Aim: To determine the effects of leaking septic tanks on groundwater quality in Owerri Municipal. Place and Duration of the Study: Department of Geosciences, Federal University of Technology Owerri, and Department of Chemistry, Alvan Ikoku Federal College of Education, Owerri, Imo State, Nigeria, between January 2013 to May 2014. Methodology: Geophysical and geochemical analysis was carried out using chemical and geophysical analyses. Owerri Municipal is located within Longitudes 6o59’E to 7o06’E and Latitudes 5o33’N. It falls within the coastal plains sands. The quality of groundwater was determined by taking samples from three locations namely Amakohia, Naze and Nekede and carrying out physiochemical analysis on each to ascertain the nature of dissolved substances in the groundwater. Also, physiochemical parameters like bulk density, porosity and permeability of the samples were determined. Description of the lithology and aquifer parameters were obtained using vertical electrical sounding method. Results: The density of the samples ranged from 1.49 to 1.98 mg/L, the porosity values are from 0.20 to 0.38 while the permeability varies from 0.053 mg/L to 2.49 mg/L. The chemical analysis revealed that some heavy metals have concentrations above the amount acceptable by WHO standards. Iron 18.6 to 63.9 mg/L, Nickel 7.5 mg/L and Manganese, 0.46 mg/L. The resistivity of the topsoil ranges from 618 m to 3800 m. An average resistivity range of 7500 m exist up to 30 m while a layer of low resistivity indicating clay and clayey sand extends to 60 m at Naze, 60 m at Nekede and 50 m at Amakohia. Beyond these depths, the resistivity is high on the average of 3500 m. Conclusion: The results showed that the subsurface is permeable which implies that traces of heavy metals present in the samples are contained in the leachets from surrounding environments either from septic tanks or from industrial activities on the surface. Groundwater quality can be improved within this environment by recommending boreholes drilled from 70 m where leachet permeability is negligible. The high concentration of some of the heavy metals is suspected to be present in the leachets which could have infiltrated as a result of human deposits and industrial activities within the environment.

Item Type: Book Section
Subjects: Research Scholar Guardian > Multidisciplinary
Depositing User: Unnamed user with email support@scholarguardian.com
Date Deposited: 31 Oct 2023 04:33
Last Modified: 31 Oct 2023 04:33
URI: http://science.sdpublishers.org/id/eprint/1896

Actions (login required)

View Item
View Item